Temporary containment walls installed in a live data center

The world's most critical facilities need reliable containment systems.

System Categories

Two systems. One sealed environment.

Wall Systems

Sealcore wall systems create clean, protected work zones inside occupied facilities while minimizing disruption to ongoing operations.

Phased buildout of containment walls in a live data hall

Dust Containment

Sealed modular panels keep construction particulate off the live floor.

Noise Reduction

Sound-attenuating construction cuts renovation noise up to 50%.

500 lb Impact Resistant

Wall panels are independently impact tested to protect and maintain containment in active environments.

Fire-Rated Options

Full-assembly panels tested to ASTM E84 Class A.

Air Systems

Sealcore air systems help control dust, airborne contaminants, and project-related particulates in mission-critical environments.

Negative air and HEPA filtration isolating construction particulate

HEPA Filtration

Captures 99.97% of airborne particles down to 0.3 microns before exhaust.

Negative Pressure Control

Maintains lower pressure inside the work zone so air flows in, not out.

Dust Mitigation

Helps prevents dust and particulates from migrating into occupied areas.

Pressure Monitoring

Continuously verifies pressure differential so containment remains properly maintained.

The Sealcore System

Why Sealcore?

STARC, the industry's leading modular containment wall system.

Trusted in data centers, healthcare, and bio/life sciences, rented, installed, and dismantled by Sealcore as a complete service. Modular panels lock into an airtight seal in virtually any configuration. You rent a sealed environment, not equipment to manage.

Learn more

Airtight Dust & Particulate Control

Modular panels seal with no gaps. Integrated negative air panels discharge filtered air and keep construction particulate off the floor, with a damper that closes automatically above 165°F.

Learn more

Negative Air & Pressure Monitoring

Negative air keeps the work zone at lower pressure than the live floor, so air flows in, never out, dust can't drift toward your racks. HEPA then captures 99.97% of particles to 0.3 microns before exhaust. Dedicated negative air and air monitor panels are manometer compatible, with a 2" rated pass through for instrumentation, and Sealcore runs continuous pressure monitoring so the zone stays verifiably isolated.

Learn more

ICRA Class V Compliant

Exceeds ICRA Class V, the infection-control risk standard used in healthcare construction, so the same sealed containment protects your live floor.

Learn more

Experience

Our crews are trained to install containment in occupied, mission-critical environments, trusted by leading hyperscale, colocation, and enterprise providers.

Learn more

Custom Space Configuration

Panels lock into an airtight seal in virtually any configuration, built to your footprint, corners, offsets, doors, and odd aisle widths.

Learn more

Capabilities

Designed for Datacenters.

Sealcore temporary containment walls: Hot-Aisle Containment

Hot-Aisle Containment

Seal HAC zones for commissioning and rack changes without downing the hall.

Sealcore temporary containment walls: Reconfigurations

Reconfigurations

Built to your footprint, corners, offsets, doors, and odd aisle widths configured to the space.

Sealcore temporary containment walls: Phased Buildout in Live Halls

Phased Buildout in Live Halls

Reconfigurable panels advance with each phase so the live side never feels the work.

By the numbers.

Downtime cost
$600K
/ hour

Average cost of unplanned data center downtime. One incident pays for years of containment.

Particulate capture
99.97%

HEPA at the 0.3 micron healthcare standard, the same spec used in operating rooms.

Install speed
~100
LF / hour

Quick deployment. Minimal disruption. Maximum protection.

Projects · Coverage

10+ YEARS

INDUSTRY EXPERIENCE ACROSS THE UNITED STATES

FAQ

Frequently asked questions

Contact

Quotes in 24 hours.

Send the scope or just the constraints - we'll have signed pricing back inside a day and a crew on-site within the week.